[1]吴明忠,杨帆.手臂系统手传振动的研究现状[J].华侨大学学报(自然科学版),2019,40(3):281-290.[doi:10.11830/ISSN.1000-5013.201901054]
 WU Mingzhong,YANG Fan.Review of Hand-Transmitted Vibration in Hand-Arm System[J].Journal of Huaqiao University(Natural Science),2019,40(3):281-290.[doi:10.11830/ISSN.1000-5013.201901054]
点击复制

手臂系统手传振动的研究现状()
分享到:

《华侨大学学报(自然科学版)》[ISSN:1000-5013/CN:35-1079/N]

卷:
第40卷
期数:
2019年第3期
页码:
281-290
栏目:
出版日期:
2019-05-20

文章信息/Info

Title:
Review of Hand-Transmitted Vibration in Hand-Arm System
文章编号:
1000-5013(2019)03-0281-10
作者:
吴明忠 杨帆
华侨大学 机电及自动化学院, 福建 厦门 361021
Author(s):
WU Mingzhong YANG Fan
College of Mechanical Engineering and Automation, Huaqiao University, Xiamen 361021, China
关键词:
手传振动 手臂振动病 手臂系统 响应特性 减振手套
Keywords:
hand-transmitted vibration hand-arm vibration disease hand-arm system response characteristics vibration-reducing golves
分类号:
TB53;X593
DOI:
10.11830/ISSN.1000-5013.201901054
文献标志码:
A
摘要:
概述手传振动的危害,介绍手传振动响应特性的测试系统和手部的握持姿势,并对手臂系统的振动响应特性及减振手套的减振性能进行综述.结果表明:工效学因素和试验条件是机械阻抗特性与振动传递率特性的主要影响因素;手传振动响应特性具体的响应幅值存在较大差异,但基本趋势大体一致;应加强手传振动响应特性和减震手套的研究,弥补相关标准存在的不足.
Abstract:
The hazards from hand-transmitted vibration, the test system for response characteristic of hand-transmitted vibration and the gripping posture of the hand were introduced first. Second, the characteristics of vibration response of the hand-arm system and the vibration-reducing effectiveness of vibration-reducing gloves were reviewed. The literatures show that ergonomic factors and experimental conditions are the main factors which take an effect on mechanical impedance and vibration transmissibility and there is a large difference on the amplitude of specific responses but their basic trends are approximately similar to each other. Research on response characteristic of hand-transmitted vibration and vibration-reducing gloves should be strengthened, improve the related standards.

参考文献/References:

[1] 中华人民共和国卫生部.工作场所物理因素测量 手传振动: GBZ/T 189.9-2007[S].北京: 中国标准出版社,2007.
[2] 《中国职业医学》编辑部.科学防治职业性手臂振动病[J].中国职业医学,2018,45(6):785.
[3] 中华人民共和国国家卫生和计划生育委员会.职业性手臂振动病的诊断: GBZ 7-2014[S].北京: 中国标准出版社,2014.
[4] 王林.正确理解和实施《职业性手臂振动病诊断标准》[J].中华劳动卫生职业病杂志,2004,22(6):473-474.DOI:10.3760/cma.j.issn.1001-9391.2004.06.030.
[5] 陈嘉斌,陈青松,王建新,等.《职业性手臂振动病的诊断》标准修订说明[J].中国职业医学,2015,42(2):212-216.DOI:10.11763/j.issn.2095-2619.2015.02.021.
[6] ADEWUSI S A,RAKHEJA S,MARCOTTE P,et al.Vibration transmissibility characteristics of the human hand-arm system under different postures, hand forces and excitation levels[J].Journal of Sound and Vibration,2010, 329(14):2953-2971.DOI:10.1016/j.jsv.2010.02.001.
[7] LAWS J.The hazards of HAVS[J].Occupational Health and Safety,1998,67(12):45-46.
[8] KUCUK H O,EYUBOGLU M,KUCUK U,et al.Occupational exposure to hand-arm vibration[J].International Journal of Cardiology,2016,203:959.DOI:10.1016/j.ijcard.2015.11.122.
[9] BRAUCH R.Vibration analysis and standards[R].Florida: AIHA Florida Spring Conference,2009.
[10] 王林.振动与振动病防治[M].北京: 科学出版社,2013.
[11] GRIFFIN M J.Handbook of human vibration[M].London: Academic Press,1990.
[12] 肖建民,郑凡颖,戴友春,等.职业性手传振动危害及其对策[J].劳动保护科学技术,1990,51(3):54-58.
[13] 黄永顺,金佳纯,温贤忠,等.2006-2012年广东省物理因素所致职业病发病特点分析和对策探讨[J].中国职业医学,2013,40(6):544-546.DOI:10.11763/j.issn.2095-2619.2013.06.014.
[14] 王林,张凯,聂继池,等.局部振动病国内研究的进展和诊断标准的修订[J].济宁医学院学报,1998,21(3):1-4.
[15] British Standards Institution.Mechanical vibration and shock-hand-arm vibration: Method for the measurement and evaluation of the vibration transmissibility of gloves at the palm of the hand: ISO 10819: 1996[S].London: British Standards Institution,1996.
[16] 中华人民共和国国家质量监督检验检疫总局,中国国家标准化管理委员会.机械振动 人体暴露于手传振动的测量和评价 第1部分 一般要求: GB/T 14790.1-2009[S].北京: 中国标准出版社,2009.
[17] British Standards Institution.Mechanical vibration and shock-human exposure-biodynamic coordinate systems: ISO 8727: 1997[S].London: British Standards Institution,1997.
[18] GURRAM R,RAKHEJA S,GOUW G J.Mechanical impedance of the human hand-arm system subject to sinusoidal and stochastic excitations[J].International Journal of Industrial Ergonomics,1995,16(2):135-145.DOI:10.101 6/0169-8141(94)00092-H.
[19] MARCOTTE P,ALDIEN Y,BOILEAU P É,et al.Effect of handle size and hand-handle contact force on the biodynamic response of the hand-arm system under zh-axis vibration[J].Journal of Sound and Vibration,2005,283(3):1071-1091.DOI:10.1016/j.jsv.2004.06.007.
[20] XU X Y S,DONG R G,WELCOME D E,et al.Vibrations transmitted from human hands to upper arm, shoulder, back, neck, and head[J].International Journal of Industrial Ergonomics,2016,62:1-12.DOI:10.1016/j.ergon. 2016.07.001.
[21] KIHLBERG S.Biodynamic response of the hand-arm system to vibration from an impact hammer and a grinder[J].International Journal of Industrial Ergonomics,1995,16(1):1-8.DOI:10.1016/0169-8141(94)00060-G.
[22] DONG R G,WELCOME D E,MCDOWELL T W,et al.Measurement of biodynamic response of human hand-arm system[J].Journal of Sound and Vibration,2006,294(4):807-827.DOI:10.1016/j.jsv.2005.12.047.
[23] MARCHETTI E,SISTO R,LUNGHI A,et al.An investigation on the vibration transmissibility of the human elbow subjected to hand-transmitted vibration[J].International Journal of Industrial Ergonomics,2017(62):82-89. DOI:10.1016/j.ergon.2017.04.001.
[24] SCALISE L,ROSSETTI F,PAONE N.Hand vibration: Non-contact measurement of local transmissibility[J].International Archives of Occupational and Environmental Health,2007,81(1):31-40.DOI:10.1007/s00420-007-019 0-3.
[25] DEWANGAN K N,TEWARI V K.Characteristics of vibration transmission in the hand-arm system and subjective response during field operation of a hand tractor[J].Biosystems Engineering,2008,100(4):535-546.DOI:10.101 6/j.biosystemseng.2008.05.002.
[26] ADEWUSI S,RAKHEJA S,MARCOTTE P.Biomechanical models of the human hand-arm to simulate distributed biodynamic responses for different postures[J].International Journal of Industrial Ergonomics,2012,42(2):249-260.DOI:10.1016/j.ergon.2012.01.005.
[27] RAKHEJA S,WU J Z,DONG R G,et al.A comparison of biodynamic models of the human hand-arm system for application to hand-held power tools[J].Journal of Sound and Vibration,2002,249(1):55-82.DOI:10.1006/jsvi.2001.3831.
[28] DONG R G,DONG J H,WU J Z,et al.Modeling of biodynamic responses distributed at the fingers and the palm of the human hand-arm system[J].Journal of Biomechanics,2007,40(10):2335-2340.DOI:10.1016/j.jbiomech.2006.10.031.
[29] WU J Z,WELCOME D E,MCDOWELL T W,et al.Modeling of the interaction between grip force and vibration transmissibility of a finger[J].Medical Engineering and Physics,2017,45:61-70.DOI:10.1016/j.medengphy.2017.04.008.
[30] International Organization for Standardization.Mechanical vibration-measurement and evaluation of human exposure to hand-transmitted vibration(Part1): General requirements: ISO 5349-1: 2001[S].Geneva: International Organization for Standardization,2001.
[31] 陆秋海,李德葆.工程振动试验分析[M].2版.北京: 清华大学出版社,2015.
[32] BURSTRÖM L.Measurements of the impedance of the hand and arm[J].International Archives of Occupational and Environmental Health,1990,62(6):431-439.DOI:10.1007/BF00379059.
[33] International Organization for Standardization.Mechanical vibration and shock-free, mechanical impedance of the human hand-arm system at the driving point: ISO 10068: 1998[S].Geneva: International Organization for Standardization,1998.
[34] 中国国家标准化管理委员会.机械振动与冲击 人体手臂系统驱动点的自由机械阻抗: GB/T 19740-2005[S].北京: 中国标准出版社,2005.
[35] CRONJÄGER L,HESSE M.Hand-arm system response to stochastic excitation[C]//Proceeding of the Fifth Conference on Hand-Arm Vibration.Kanzawa: [s.n.],1990:85-86.
[36] BURSTRÖM L.The influence of biodynamic factors on the mechanical impedance of the hand and arm[J].International Archives of Occupational and Environmental Health,1997,69(6):437-446.DOI:10.1007/s004200050172.
[37] JANDÁK Z.Driving-point mechanical impedance of the hand-arm system at exposure to stochastic vibration[C]//Proceedings of the Eighth International Conference on Hand-Arm Vibration.Umea: [s.n.],1998:111-112.
[38] ALDIEN Y,MARCOTTE P,RAKHEJA S,et al.Influence of hand-arm posture on biodynamic response of the human hand-arm exposed to zh-axis vibration[J].International Journal of Industrial Ergonomics,2006,36(1):45-59.DOI:10.1016/j.ergon.2005.07.001.
[39] BESA A J,VALERO F J,SUÑER J L,et al.Characterisation of the mechanical impedance of the human hand-arm system: The influence of vibration direction, hand-arm posture and muscle tension[J].International Journal of Industrial Ergonomics,2007,37(3):225-231.DOI:10.1016/j.ergon.2006.10.019.
[40] FREIVALDS A.Biomechanics of the upper limbs mechanics, modeling and musculoskeletal injuries[M].Boca Raton: CRC Press,2004.DOI:10.1080/00140130600971127.
[41] DONG R G,WELCOME D E,XU X S,et al.Mechanical impedances distributed at the fingers and palm of the human hand in three orthogonal directions[J].Journal of Sound and Vibration,2012,331(5):1191-1206.DOI:10.101 6/j.jsv.2011.10.015.
[42] GURRAM R,RAKHEJA S,BRAMMER A J.Driving-point mechanical impedance of the human hand-arm system: Synthesis and model development[J].Journal of Sound and Vibration,1995,180(3):437-458.DOI:10.1006/jsvi.1995.0089.
[43] DONG R G,RAKHEJA S,MCDOWELL T W,et al.Estimation of the biodynamic responses distributed at fingers and palm based on the total response of the hand-arm system[J].International Journal of Industrial Ergonomics,2010,40(4):425-436.DOI:10.1016/j.ergon.2010.02.001.
[44] WELCOME D E,DONG R G,XU X S,et al.An examination of the vibration transmissibility of the hand-arm system in three orthogonal directions[J].International Journal of Industrial Ergonomics,2015,45(2):21-34.DOI:10.1016/j.ergon.2014.11.001.
[45] DONG R G,RAKHEJA S,SMUTZ W P,et al.Effectiveness of a new method(TEAT)to assess vibration transmissibility of gloves[J].International Journal of Industrial Ergonomics,2002,30(1):33-48.DOI:10.1016/S0169-8141(02)00076-8.
[46] International Organization for Standardization. Human response to vibration: Measuring instrumentation: ISO 8041: 2005[S].Geneva: International Organization for Standardization,2005.
[47] HEWITT S.Assessing the performance of anti-vibration gloves: A possible alternative to ISO 10819: 1996[J].The Annals of Occupational Hygiene,1998,42(4):245-252.DOI:10.1016/s0003-4878(98)00030-1.
[48] XU X S,WELCOME D E,MCDOWELL T W,et al.The vibration transmissibility and driving-point biodynamic response of the hand exposed to vibration normal to the palm[J].International Journal of Industrial Ergonomics,2011,41(5):418-427.DOI:10.1016/j.ergon.2011.05.007.
[49] ABRAMS C F,SUGGS C W.Chain saw vibration: Isolation and transmission through the human arm[J].Transactions of the American Society of Agricultural Engineers,1969,12(4):423-425.DOI:10.13031/2013.38856.
[50] WU J Z.Three-dimensional finite element simulations of the dynamic response of a fingertip to vibration[J].Journal of Biomechanical Engineering,2008,130(5):054501.DOI:10.1115/1.2947199.
[51] WU J Z,DONG R G,WELCOME D E,et al.A method for analyzing vibration power absorption density in human fingertip[J].Journal of Sound and Vibration,2010,329(26):5600-5614.DOI:10.1016/j.jsv.2010.07.022.
[52] MANSFIELD N J.Human response to vibration[M].New York: CRC Press,2005.
[53] CONCETTONI E,GRIFFIN M.The apparent mass and mechanical impedance of the hand and the transmission of vibration to the fingers, hand, and arm[J].Journal of Sound and Vibration,2009,325(3):664-678.DOI:10.1016/j.jsv.2009.03.033.
[54] PAN D,XU X S,WELCOME D E,et al.The relationships between hand coupling force and vibration biodynamic responses of the hand-arm system[J].Ergonomics,2017,61(6):1-38.DOI:10.1080/00140139.2017.1398843.
[55] DONG R G,MCDOWELL T W,WELCOME D E,et al.Correlations between biodynamic characteristics of human hand-arm system and the isolation effectiveness of anti-vibration gloves[J].International Journal of Industrial Ergonomics,2005,35(3):205-216.DOI:10.1016/j.ergon.2004.08.009.
[56] DONG R G,WELCOME D E,PETERSON D R,et al.Tool-specific performance of vibration-reducing gloves for attenuating palm-transmitted vibrations in three orthogonal directions[J].International Journal of Industrial Ergonomics,2014,44(6):827-839.DOI:10.1016/j.ergon.2014.09.007.
[57] 李建庆,杨晓英,于永中.防振手套等护具减振效果的研究[J].中华劳动卫生职业病杂志,2000,18(3):191-192.DOI:10.3760/cma.j.issn.1001-9391.2000.03.032.
[58] 吴国梁.抗振手套及其传递特性的试验研究[J].东南大学学报(自然科学版),1991,21(3):129-133.
[59] 汪先国,罗继高,蹇开林.橡胶隔振器在某型号摩托车手传振动优化中的应用[J].重庆理工大学学报(自然科学版),2015,29(10):83-88.DOI:10.3969/j.issn.1674-8425(z).2015.10.015.
[60] HAMOUDA K,RAKHEJA S,DEWANGAN K N,et al.Fingers vibration transmission and grip strength preservation performance of vibration reducing gloves[J].Applied Ergonomics,2018,62:121-138.DOI:10.1016/j.ergon.2016.11.012.
[61] WELCOME D E,DONG R G,XU X S,et al.The effects of vibration-reducing gloves on finger vibration[J].International Journal of Industrial Ergonomics,2014,44(1):45-59.DOI:10.1016/j.ergon.2013.10.003.
[62] 赖雅琳,吴明忠.粘弹性材料减振垫的设计方法分析[J].华侨大学学报(自然科学版),2008,29(2):319-320.DOI:10.11830/ISSN.1000-5013.2008.02.0319.

备注/Memo

备注/Memo:
收稿日期: 2019-01-26
通信作者: 吴明忠(1978-),男,讲师,博士研究生,主要从事振动分析与控制、人机工程学的研究.E-mail:jdwmz62@hqu.edu.cn.
基金项目: 国家自然科学基金重点资助项目(61733006); 福建省教育厅科研课题(JAT160028); 福建省泉州市科技计划项目(2018Z016)
更新日期/Last Update: 2019-05-20