[1]洪俊明.垃圾沥滤液氢氧化钙混凝-氨吹脱预处理[J].华侨大学学报(自然科学版),2009,30(5):546-548.[doi:10.11830/ISSN.1000-5013.2009.05.0546]
 HONG Jun-ming.Experimental Study on Municipal Solid Waste Incineration Leachate Treatment Using Lime Coagulation-Air Stripping Process[J].Journal of Huaqiao University(Natural Science),2009,30(5):546-548.[doi:10.11830/ISSN.1000-5013.2009.05.0546]
点击复制

垃圾沥滤液氢氧化钙混凝-氨吹脱预处理()
分享到:

《华侨大学学报(自然科学版)》[ISSN:1000-5013/CN:35-1079/N]

卷:
第30卷
期数:
2009年第5期
页码:
546-548
栏目:
出版日期:
2009-09-20

文章信息/Info

Title:
Experimental Study on Municipal Solid Waste Incineration Leachate Treatment Using Lime Coagulation-Air Stripping Process
文章编号:
1000-5013(2009)05-0546-03
作者:
洪俊明
华侨大学化工学院
Author(s):
HONG Jun-ming
College of Chemical Engineering, Huaqiao University, Quanzhou 362021, China
关键词:
垃圾沥滤液 氢氧化钙 混凝 氨吹脱 氨氮
Keywords:
solid waste leachate calcium hydroxidl coagulation air-stripping ammonia nitrogen
分类号:
X703
DOI:
10.11830/ISSN.1000-5013.2009.05.0546
文献标志码:
A
摘要:
采用氢氧化钙混凝-氨吹脱法,对垃圾沥滤液进行预处理,研究氢氧化钙的投加量、pH值、温度和气液比等对混凝-氨吹脱率的影响.结果表明,在垃圾沥滤液中,投加6 g.L-1氢氧化钙,可将沥滤液的pH值调到10.5; 混凝预处理后,对总磷的去除率可达80%,氨氮的去除率为15%~30%,对化学需氧量的去除率不高.垃圾沥滤液氨吹脱过程中,当pH值为10.5时,氨吹脱率可达到65%; 而当气液比为3000,水温为45℃以上,填料质量分数为50%的条件下,氨吹脱率可达到85%以上.
Abstract:
Lime coagulation-air stripping process was used to treat leachate of municipal solid waste incineration plants’ stockroom.The effects of pH,gas/liquid ratio,temperature and filler packing ratio on the stripping performance were studied.The results show that when the pH of leachate was adjusted to 10.5 after put into 6 g·L-1 Ca(OH)2,the removal ratio of total phosphor was over 80%; the removal ratio of ammonia and nitrogen is 15%~30%.The removal efficiency became lower due to the soluble CODCr presented in influent.In conditions where pH=10.5,gas/liquid ratio is 3 000 times,the leachate temperature was over 45 ℃,and the filler packing ratio was 50%,over 85% of ammonia nitrogen was removed by the air stripping.

参考文献/References:

[1] 何品晶, 冯军会, 瞿贤. 生活垃圾焚烧厂贮坑沥滤液的污染与可处理特性 [J]. 环境科学研究, 2006(2):86-89.doi:10.3321/j.issn:1001-6929.2006.02.023.
[2] 兰建伟, 颜学宏, 曾贤桂. 垃圾焚烧厂中沥滤液的处理 [J]. 工程设计与建设, 2004(5):39-42.doi:10.3969/j.issn.1673-8993.2004.05.012.
[3] CHEUNG K C, CHU L M, WONG M H. Ammonia stripping as a pretreatment for landfill leachate [J]. Water, Air & Soil Pollution, 1997, (1-2):209-221.
[4] 国家环境保护局《水和废水监测分析方法》编委会. 水和废水监测分析方法 [M]. 北京:中国环境科学出版社, 2002.
[5] TCHOBANOGLOUS G, BURTON F L, STENSEL H D. Wastewater engineering:Treatment and reuse [M]. New York:McGraw-Hill, 2001.
[6] 王文斌, 董有, 刘士庭. 吹脱法去除垃圾渗滤液中的氨氮研究 [J]. 环境工程学报, 2004(5):51-53.doi:10.3969/j.issn.1673-9108.2004.06.013.