[1]刘恒,任洪亮.非分散红外二氧化碳检测仪研制[J].华侨大学学报(自然科学版),2017,38(6):854-857.[doi:10.11830/ISSN.1000-5013.201507038]
 LIU Heng,REN Hongliang.Carbon Dioxide Detector Based on Non-Dispersed Infrared Principle[J].Journal of Huaqiao University(Natural Science),2017,38(6):854-857.[doi:10.11830/ISSN.1000-5013.201507038]
点击复制

非分散红外二氧化碳检测仪研制()
分享到:

《华侨大学学报(自然科学版)》[ISSN:1000-5013/CN:35-1079/N]

卷:
第38卷
期数:
2017年第6期
页码:
854-857
栏目:
出版日期:
2017-11-20

文章信息/Info

Title:
Carbon Dioxide Detector Based on Non-Dispersed Infrared Principle
文章编号:
1000-5013(2017)06-0854-04
作者:
刘恒 任洪亮
华侨大学 信息科学与工程学院, 福建 厦门 361021
Author(s):
LIU Heng REN Hongliang
College of Information Science and Engineering, Huaqiao University, Xiamen 361021, China
关键词:
CO2 气体检测 Lambert-beer定律 热释电传感器 光源调制 滤波放大电路
Keywords:
CO2 gas detection Lambert-beer low pyroelectric sensors light source modulation filtering-amplifying circuit
分类号:
X853
DOI:
10.11830/ISSN.1000-5013.201507038
文献标志码:
A
摘要:
设计一种电调制、一体化的二氧化碳体积分数检测系统.该系统基于CO2气体分子对红外光的特征吸收和Lambert-beer定律,采用双通道设计,由热释电传感器检测到的两路信号经过1 Hz低通放大电路处理后,输入示波器显示.为了避免光源波动对测量结果的影响,采用5 V稳压电路驱动红外光源,单片机对其进行1 Hz亮灭调制.对两路输出信号进行计算,可得CO2体积分数.结果表明:检测仪量程为0%~80%,响应时间小于1.5 s.
Abstract:
A compact non-dispersed infrared CO2 measuring system using electrical modulated infrared source is designed. The system uses dual channel pyroelectric sensors to detect CO2 molecular based on characteristic infrared absorption and Lambert-beer low. Two channels signals detected from pyroelectric sensor are filtered by 1 Hz low pass amplifier circuit. The measured result is displayed on an oscilloscope. In order to avoid measurement result is affected by light source fluctuation, the infrared light source is powered by 5 V voltage regulator circuit, and it is switched on and off with 1 Hz modulation frequency controlled by a single chip. The volume fractions of CO2 is obtained according to the calculation of the tow output signal. Result shows that the detector has the measurement rang of 0%-80%, the response time less than 1.5 s.

参考文献/References:

[1] 陈俊武,陈香生,胡敏.中国低碳经济前景刍议(下): 中国减少碳排放措施[J].中外能源,2015,20(4):1-14.
[2] ROBERT F,THOMAS T.An automotive bisource spectroscopic carbon dioxide sensor with pressure compensation[J].Sensors and Actuators B,2007,127(1): 82-88.DOI:10.1016/j.snb.2007.07.005.
[3] QIAN Weikang,HUANG Xiaoyin,QIAN Jianqiu.Research of implementation for multi-component gas monitoring based on principle of non-dispersive infrared[J].Computer Engineering and Applicating,2012,48(S2):92-95.
[4] 王文萃,栾美生,于彤彦.红外甲烷气体检测仪的设计以及干扰分析[J].红外技术,2009,31(8):458-460.
[5] 周世勋.量子力学教程[M].北京:高等教育出版社,2009.
[6] SIPIOR J,EICHHOM L,LAKOWICZ J R. Phase fluorometric optical carbon dioxide gas sensor for fermentation off-gas monitoring[J].Biotechnol Prog,1996,12(2):266-271.DOI:10.1021/bp960005t.
[7] WERLE P.A review of recent advances in semiconductor laser based gas monitors[J].Spectrochemical Acta Part A:Molecular and Biomolecular Spectroscopy,1998,54(2):197-236.DOI:10.1016/S1386-1425(97)00227-8.
[8] 赵玲,赵燕,何秀丽,等.基于超薄钽酸锂晶片及炭黑吸收层的热释电探测器[J].纳米技术与精密工程,2013,12(1):44-50.DOI:10.3969/j.issn.1672-6030.2014.01.008.
[9] 任洪亮.总有机碳分析仪信号处理算法的分析[J].华侨大学学报(自然科学版),2014,35(2):142-145.
[10] 侯卫国,谷城.压控电压源二阶低通有源滤波电路设计与仿真[J],实验技术与管理,2014,31(10):103-106.
[11] 余明扬,余斌,潘俊东,等.CLC滤波电路参数对纹波抑制的影响[J].计算机仿真,2014,31(2):183-186.

备注/Memo

备注/Memo:
收稿日期: 2015-07-26
通信作者: 任洪亮(1980-),男,副教授,博士,主要从事光电检测及光学微操控仪器研发的研究.E-mail:renhongliang@hqu.edu.cn.
基金项目: 福建省自然科学基金资助项目(2012J05120); 福建省泉州市科技计划资助项目(2012Z95); 华侨大学科技文化创新基金资助项目(201510385040)
更新日期/Last Update: 2017-11-20