关键词:
混合有源电力滤波器 谐波抑制 高压直流输电系统 谐波补偿 MATLAB仿真
Keywords:
hybrid active power filter harmonic suppression high-voltage direct current transmission system Harmonic compensation MATLAB simulation
分类号:
TM711
DOI:
10.11830/ISSN.1000-5013.201702015
文献标志码:
A
摘要:
针对高压直流输电系统(HVDC)换流站的交流侧谐波造成了电能质量下降的问题,在传统混合有源电力滤波器的基础上提出一种新结构——混合有源电力滤波器(HAPF).即将有源电力滤波器(APF)部分与基波谐振支路并联后,以一双调谐滤波器作为注入支路,同时又独立挂载一双调谐滤波器,以无源电力滤波器(PPF)滤除一部分谐波,APF部分滤除一部分谐波.从注入支路的阻抗特性、无功静补偿能力、谐波抑制特性和系统的稳定性几个方面分析混合有源电力滤波器的优越性,并利用MATLAB/SIMULINK平台对所提的新结构进行仿真分析
Abstract:
A new structure, hybrid active power filter(HAPF), has been proposed on the basis of traditional hybrid active power filter to solve problems about decline of power quality caused by the high voltage direct current(HVDC)transmission system on the ac side harmonics. In the new structure, the active power filter(APF)has been made in parallel with the fundamental wave resonance branch, then with a pair of tuned filter as the injection branch, and at the same time a pair of tuned filter been independently mounted to filter part of the harmonic through passive power filter(PPF)as well as APF. Several advantages of the hybrid active power filter have been analyzed from the injection branch impedance characteristics, the reactive power static compensation capacity, harmonic suppression characteristics and the stability of the system. And the new structure has been simulated in the MATLAB/SIMULINK. The experimental results show that the hybrid active power filter has good harmonic compensation performance.

参考文献/References:

[1] 帅智康,罗安,刘定国,等.串联谐振注入式混合型有源电力滤波器及滤波特性分析[J].电工技术学报,2009,24(5):125-134.
[2] 王小伟,赵伟,涂春鸣,等.双谐振注入式混合有源电力滤波器及控制方法[J].电力系统自动化,2010,34(2):59-63.
[3] 孟金岭,赵伟,林国营,等.双谐振注入混合型有源电力滤波器特性[J].电力系统保护与控制,2016,44(3):32-38.
[4] 孙浩,周雒维.并联混合型有源电力滤波器滤波特性分析[J].继电器,2007,35(8):61-64.
[5] 帅智康,罗安,范瑞祥,等.注入式混合有源电力滤波器的注入支路设计[J].电力系统自动化,2007,31(5):57-60.
[6] 高东辉,杜少武,张长征.改进型混合级联多电平有源电力滤波器的研究[J].电力系统保护与控制,2014,42(1):40-46.
[7] 方凤才.一种基于调谐频率设计双调谐滤波器的新方法[J].天津师范大学学报(自然科学版),2014,34(3):47-51.
[8] 范瑞祥,罗安,周柯,等.并联混合型有源电力滤波器的建模和控制策略分析[J].中国电机工程学报,2006,26(12):55-61.
[9] 康润生,王梦荷,连欢,等.可用于高压电网的新型混合滤波器研究[J].河南理工大学学报(自然科学版),2015,34(5):695-701.
[10] 夏向阳,徐林菊,刘飞龙.考虑谐振的混合型有源滤波器参数优化配置[J].电力系统及其自动化学报,2012,24(6):31-35.
[11] RAHMANI S,HAMADI A,AL-HADDAD K.A Lyapunov-function-based control for a three-phase shunt hybrid active filter[J].IEEE Transactions on Industrial Electronics,2012,59(3):1418-1429.
[12] 赵畹君.高压直流输电工程技术[M].北京:中国电力出版社,2010:10-13.
[13] 邹伯敏.自动控制理论[M].北京:机械工业出版社,2007:62-66.
[14] 洪雪梅,金福江,李扬森,等.三相正弦波逆变器容错控制[J].华侨大学学报(自然科学版),2016,37(4):497-501.
[15] 陈宇,郑力新.利用自适应遗传算法优化滤波电路参数[J].华侨大学学报(自然科学版),2010,31(3):272-274.

备注/Memo

备注/Memo:
收稿日期: 2016-03-09
通信作者: 凃玲英(1963-),女,副教授,主要从事信号与信息处理、嵌入式技术的研究.E-mail:947392311@qq.com.
基金项目: 湖北省自然科学基金资助项目(2014CFB585)