[1]杜欣慧,胡殿霞.高压直流输电中换流器保护电路的仿真分析[J].华侨大学学报(自然科学版),2013,34(2):134-138.[doi:10.11830/ISSN.1000-5013.2013.02.0134]
 DU Xin-hui,HU Dian-xia.Simulation and Analysis of Protection Devices for Converter Station in High Voltage Direct Current Transmission System[J].Journal of Huaqiao University(Natural Science),2013,34(2):134-138.[doi:10.11830/ISSN.1000-5013.2013.02.0134]
点击复制

高压直流输电中换流器保护电路的仿真分析()
分享到:

《华侨大学学报(自然科学版)》[ISSN:1000-5013/CN:35-1079/N]

卷:
第34卷
期数:
2013年第2期
页码:
134-138
栏目:
出版日期:
2013-03-20

文章信息/Info

Title:
Simulation and Analysis of Protection Devices for Converter Station in High Voltage Direct Current Transmission System
文章编号:
1000-5013(2013)02-0134-05
作者:
杜欣慧 胡殿霞
太原理工大学 电气与动力工程学院, 山西 太原 030024
Author(s):
DU Xin-hui HU Dian-xia
School of Electrical and Power Engineering, Taiyuan University of Technology, Taiyuan 030024, China
关键词:
高压直流输电 过电压 过电流 阻容缓冲器 电子保护电路 模糊比例积分控制
Keywords:
high-voltage direct current transmission over-voltage over-current resistance capacity buffer electronic protection circuit fuzzy proportion integration control
分类号:
TM772
DOI:
10.11830/ISSN.1000-5013.2013.02.0134
文献标志码:
A
摘要:
针对高压直流输电系统换流器中晶闸管的过电压、过电流故障,采用阻容缓冲器进行器件自身保护,以及基于模糊比例积分(PI)控制理论的电子保护电路作为控制系统保护.仿真结果表明:阻容缓冲电路使系统跟随性更好,系统超调量得到改善,提高了换流站运行的可靠性和稳定性;模糊自适应 PI控制器能实时调整PI参数,使整流电流具有良好的跟踪性和故障恢复性,保证高压直流输电的正常、可靠和稳定运行.
Abstract:
According to the over-voltage and over-current failure analysis of thyristor converter in the high-voltage direct current(HVDC)transmission system, the resistance and capacitance buffer for their own protection and electronic protection circuit based on the fuzzy PI(proportion integration)control theory as control system protection is used for protection design in the paper. The simulation result shows that the application of resistance and capacitance buffer is in better traceability, lower overshoot and improves reliability and stability of converter running. Fuzzy PI controller can adjust the PI parameter in time and makes DC current having good traceability and recovery. It ensures the high-voltage direct current transmission system in normal, reliable and stable operation.

参考文献/References:

[1] 姜姝.HVDC换流器故障分析及保护原理研究[D].广州:华南理工大学,2010:2-3.
[2] 韩民晓,文俊,徐永海.高压直流输电原理与运行[M].北京:机械工业出版社,2008:152-155.
[3] 王兆安,黄俊.电子电子技术[M].北京:机械工业出版社,2008:37-40.
[4] 田杰.高压直流控制保护系统的设计与实现[J].电力自动化设备,2005,25(9):10-14.
[5] 张颖,邰能灵,徐斌.高压直流输电系统阀短路保护动作特性分析[J].电力系统自动化, 2011,35(8):97-102.
[6] 吴振峰.喷管精锻中频感应加热控制系统关键技术研究[D].武汉:华中科技大学,2005:26-28.
[7] 郝勇,刘云霞,曾继伦.基于指数恢复模型的晶闸管阻容吸收参数设计[J].电气技术,2010(2):20-23.
[8] DASH P K,SAMANTRAY S R.Phase selection and fault section identification in thyristor controlled series compensated line using discrete wavelet transform[J].Electrical Power Energy Systems,2004,26(9):725-732.
[9] 朱良红,王永初.模糊与积分混合控制器[J].华侨大学学报:自然科学版,2003,24(3):285-289.
[10] 柳在鑫,王进戈,朱维兵,等.双圆弧优化算法的足球机器人路径规划[J].华侨大学学报:自然科学版,2008,29(2):190-193.

备注/Memo

备注/Memo:
收稿日期: 2012-09-25
通信作者: 杜欣慧(1965-),女,教授,博士,主要从事电力系统运行与控制的研究.E-mail:duxinhui211@163.com.
更新日期/Last Update: 2013-03-20